Abstract

Multiple-channel electrochemical cells are used for the electrocoagulation treatment of pollutants, but sometimes their use can be limited because of lack of knowledge of both hydrodynamic and current distribution performance. Most of the research devoted to electrocoagulation processes, do not present a preliminary hydrodynamic study of the selected cell. Thus, in this paper the importance of having a hydrodynamic characterization and current distribution analysis of a multi-channel electrochemical cell is highlighted. Studies of primary current distribution and, hydrodynamics were supported on applications of the COMSOL Multhiphysics{trade mark, serif} and FLUENT{trade mark, serif} software, respectively. The flow path was described by the residence time distribution (RTD) method. The current distribution analysis showed that a better distribution is obtained when an interelectrode gap of 3 cm is chosen. The RTD charts and the flow distribution described accurately channeling sections and stagnant zones that must be taken into account, since channeling reduce the entrapment of mud and stagnant zones promote the formation of clots.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.