Abstract

We present the results of an experimental investigation of the energy balance of a Ballard MK5-E proton exchange membrane fuel cell (PEMFC) stack. We have investigated the transient phenomena that occur during PEMFC stack warm-up, under load switching, and when the PEMFC stack is connected to a DC/AC inverter. A simple and convenient model describing the polarization curve as a function of the temperature is presented and validated by our experimental data. We also present experimental results on the increase PEMFC stack performance as a function of the current density for different oxygen concentrations of the oxidant gas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.