Abstract

The typical data presentation by flow cytometry of platelet suspensions stimulated with calcium ionophore A-23187, thrombin, C5b-9, or other agonists shows a unimodal decrease (or 'left-shift') in forward angle light scatter. Many reports in the literature interpret these findings as indicative of the appearance of small membranous microparticles generated from the platelets as part of the activation response. Investigators may attempt to quantify the microparticles by calculation of the percentage of counts falling below a gate set around the forward angle light scatter distribution of fresh, non-activated platelets. We believe that this approach can lead to erroneous results unless the total particle count in the sample is also determined. The true change in total particle count in a platelet sample is easily estimated on the flow cytometer by adding a known amount of fluorescent beads to the platelet suspension and noting a change in the ratio of bead versus non-bead event counts as a result of the stimulus added. Using this technique under settings considered routine for platelet analysis on a FACScan flow cytometer (Becton-Dickinson), we have found that particle counts increased very little (less than a doubling) in platelet suspensions stimulated with 1-10 w M A-23187 or 0.01-0.5 U/ml thrombin or with sera from patients with diagnosed heparin-induced thrombocytopenia (HIT). Only by employing high sensitivity settings for signal thresholding on orthogonal light scatter, combined with fluorescence gating on high prevalence surface antigens, were we able to detect significant increases (5- or 6-fold) in total particle count in the same experiments. The new events we observed were separated by a decade or more (log scale) from intact platelets on the light scatter plots and fluorescence histograms in a bimodal distribution. We postulate that the unimodal-shifted population of events seen under routine settings after stimulation with ionophore is really degranulated platelets, and only the much smaller new modal subpopulation represents microparticles released as new entities into the platelet suspension. We conclude that without high sensitivity settings for data acquisition, it is most likely incorrect to claim that the left-shifted events on flow cytometry light scatter plots appearing contiguous with the distribution of activated platelets are released microparticles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.