Abstract

The input and output samples from existing large-scale municipal solid waste incinerator (MSWI) were collected and analyzed for polychlorinated dibenzo-р-dioxins and dibenzofurans (PCDD/Fs) in this study, aiming to evaluate PCDD/F characteristic and the corresponding mass balance through the whole system. The grate-type MSWI is equipped with semi-dry scrubber, activated carbon injection, and bag filter as air pollutant control devices (APCDs). Results showed that on the output side, the stack gas, bottom ash and fly ash presented their mean dioxin levels of 0.078ng I-TEQ/Nm3, 12.94ng I-TEQ/kg and 858ng I-TEQ/kg, respectively, and showed large similarities in congener profiles. Instead, on the input side, the municipal solid waste (MSW) presented a mean dioxin level of 15.56ng I-TEQ/kg and a remarkable difference in congener profiles compared with those of the output. The dioxin mass balance demonstrated that the annual dioxin input value was around 5.38g I-TEQ/yr, lower than the total output value (7.62g I-TEQ/yr), signifying a positive dioxin balance of about 2.25g I-TEQ/yr.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.