Abstract
Material homogeneity is critical in achieving high-performance in all types of radiation detectors. This requirement is not inevitably satisfied in today's commercial detector-grade CdZnTe (CZT) material because it contains high concentrations of extended defects, in particular, Te inclusions, dislocation networks, and twin- and subgrain-boundaries that affect the energy resolution and the efficiency of the devices. Defects, such as grain boundaries and cracks that completely block charge-carrier transport are impermissible in CZT radiation-detectors at concentrations exceeding certain threshold values. Our group in Brookhaven National Laboratory (BNL) conducts systematic studies, detailing the roles of crystal defects in CZT detectors and the mechanisms underlying their formation and effects. We employ infrared transmission microscopy, white beam X-ray diffraction topography, and high-spatial-resolution X-ray response mapping to identify particular types of defects and reveal their relationship with the devices' performances. In this article, we summarize some of the most important results that our group obtained over the past 5 years.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.