Abstract

Pulsed field ablation (PFA) is increasingly used in clinical practice for the treatment of atrial fibrillation. While the susceptibility of erythrocytes to electroporation is well established, the effect of cardiac PFA technologies on hemolysis has remained underreported. The aim of this study was to investigate the incidence, severity, and clinical impact of PFA-induced hemolysis. We included n=145 patients undergoing atrial fibrillation catheter ablation with a pentaspline PFA catheter (biphasic, bipolar pulses of 2 kV) and n=70 patients receiving radiofrequency ablation (40-90 W) at 4 high-volume European centers. The lesion set comprised pulmonary vein isolation for paroxysmal atrial fibrillation and pulmonary vein isolation±additional lesions for persistent atrial fibrillation. Hemolysis and renal function biomarkers were analyzed in blood samples at baseline, at the end of ablation, and 24 hours after the procedure. Baseline characteristics were well balanced between groups (overall mean, 65.7±9.4 years; 69.3% male). The ablation procedures comprised a mean of 61.6±27.4 PFA deliveries and 26.3±15.0 minute RF duration. Hemolysis was detected in 94.3% versus 6.8% of patients after PFA versus radiofrequency ablation (P<0.001): PFA was associated with significantly lower haptoglobin levels (0.5±0.4 versus 1.0±0.4 g/L), while free plasma hemoglobin (592.8±330.6 versus 147.8±183.0 mg/L), bilirubin (21.3±11.3 versus 14.8±8.8 µmol/L), and LDH (lactate dehydrogenase, 352.7±115.7 versus 253.2±56.5 U/L) were significantly higher after PFA versus radiofrequency ablation (all P<0.001). Hemolysis correlated with the number of PFA deliveries (r=0.62 [95% CI, 0.33-0.80]; P<0.001), with the highest severity occurring ≥54 PFA deliveries. After PFA, hemoglobinuria occurred in 36.4%, while creatinine increase was higher in patients with baseline glomerular filtration rate <50 mL/min versus baseline glomerular filtration rate >50 mL/min (Δcrea, 27.0±103.1 versus -0.2±12.1 µmol/L; P=0.010). Intravascular hemolysis is a frequent finding after PFA and increases with the number of PFA deliveries. Until the clinical impact of PFA-associated hemolysis is fully elucidated, a careful titration of PFA deliveries during the ablation procedure is warranted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.