Abstract
AbstractAn experimental study has been conducted to elucidate characteristics of transient heat transfer during quenching of a vertical hot surface with a falling liquid film. The experiment was done at atmospheric pressure for the following conditions: an initial surface temperature from 200 to 400°C, a subcooling of 20– 80 K, average velocity of 0.52– 1.24 m/s, and the block material is copper and carbon steel. The surface temperature and heat flux are estimated from the measured temperatures in the block during the quench by a two‐dimensional inverse solution. It follows that as the position of wetting advances downward, the position at which the heat flux becomes a maximum also advances downward. The time at which the position of maximum heat flux begins to move is one of the most important parameters and can be predicted by a proposed correlation. In addition, it is revealed that the maximum heat flux for copper depends on the length to which it occurs from the leading edge. © 2007 Wiley Periodicals, Inc. Heat Trans Asian Res, 36(6): 345– 360, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/htj.20167
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.