Abstract

The purpose of this study was to investigate the characteristics of objective ocular surface parameters using non-invasive objective instruments in children with myopia who are candidates for orthokeratology lens wear. Children with myopia who are candidates for orthokeratology lens wear were retrospectively investigated. The subjects were divided into three age groups. The Keratograph 5M and LipiView interferometry were used to assess non-invasive tear meniscus height (TMH), non-invasive tear film break-up time (NIBUT), conjunctival hyperemia redness score (RS), meibomian gland loss (MGL) score, lipid layer thickness (LLT), and blink pattern analysis, including the number of partial blinks (PB) and total blinks (TB), as well as the partial blink rate (PBR). A total of 1119 children with myopia (2070 eyes) aged 7-18years were selected. The mean TMH, NIBUT, and LLT of the subjects was 0.21mm, 12.45s, and 65.28nm, respectively. The mean RS and upper and lower MGL scores were 0.64, 1.00, and 1.06, respectively. The mean PB, TB, and PBR was 5.13, 6.46, and 0.81, respectively. Age was significantly correlated to all ocular surface parameters (p = 0.00), except for PB. NIBUT and LLT did not differ between male participants and female participants (all p > 0.05). TMH, RS, and upper and lower MGL were significantly higher in male participants than in female participants (all p < 0.01). In addition, NIBUT was positively associated with TMH (r = 0.13, p = 0.00) and LLT (r = 0.28, p = 0.00). Both upper and lower MGL were positively correlated with TMH, PB, and TB (all p = 0.00), whereas upper MGL was negatively correlated with NIBUT and LLT (all p < 0.05). TB was negatively correlated with NIBUT and LLT (all p = 0.00). PB had no relation with TMH, NIBUT, and LLT (all p > 0.05). In addition, PBR was positively correlated with NIBUT and LLT (all p = 0.00) but not with TMH, RS, or MGL (all p > 0.05). Overall, 57.00% had a TMH ≤ 0.2mm, 43.20% had a NIBUT ≤ 10s, 48.10% had an LLT ≤ 60nm, and 88.10% had a PBR > 0.4. Child orthokeratology candidates have enhanced tear secretion and increased meibomian gland deficiency with aging. In addition, the adult dry eye diagnostic criteria may apply to orthokeratology candidates aged 12-18years but should be lower for younger candidates. Given the proportion of abnormal risk, it is necessary to assess tear film status and blink pattern by reliable and feasible objective examination before fitting orthokeratology.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call