Abstract
Experimental investigation of the characteristics of the ammonia maser is given and compared with theory. Observed saturation characteristics agree fairly well with the theory descibed in the previous paper. The change of oscillation frequency shows the expected increase with focuser voltage which arises from unresolved hyperfine structure of the 3,3 line. Small discrepancies are explained by the velocity distribution and different saturation of each hyperfine component. Frequency pulling due to cavity detuning was measured in detail and compared with theory. Thus the velocity spread of the effective molecules in the cavity can be estimated as roughly ±30%. Tentative estimate of the center frequency on U T 2 is compared with other measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.