Abstract

Summary Five steam injectors were tested to determine the extent of high-frequency temperature variations in the fluid downstream from the point of steam injection. The injectors were of three basic design types: tangential, venturi, and nozzle. They were tested with water and, in addition, two were tested with whole milk. The magnitude and period of temperature fluctuations were obtained with a thin-film platinum resistance thermometer. The variations were recorded on 35 mm film from a temperature trace displayed on a high-gain oscilloscope. Periodic temperature variations occurred in the downstream holding sections of steam injection heaters and varied with the type of injector. A tangential injector with a single steam port showed the most downstream temperature variation with water. The venturi design showed the least variation. Temperature fluctuations within the fluid stream decreased rapidly along the downstream holding sections and were nearly constant at approximately 20 in. from the point of steam injections. Whole milk showed lower temperature variations than water.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.