Abstract

In order to clarify the measuring error on differential-pressure-type flowmetering under the conditions of compressible flow with pulsation, the effects of fluid compressibility, beta ratio, upstream pipe length, pulsation intensity and Strouhal number on the error have been investigated respectively, by experiment and unsteady compressible flow analysis. The characteristics of the error E with the Strouhal number, St, are plotted indirectly and compactly, by introducing the variation of MR (ratio of mass flow amplitude in an unsteady flow case to that of quasi steady flow case) with St. This curve makes it possible to estimate the error curves qualitatively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.