Abstract

Purpose:To evaluate the magnitudes and axis orientation of anterior corneal astigmatism (ACA) and posterior corneal astigmatism (PCA), the ratio of ACA to PCA, and the correlation between ACA and PCA in the different stages of keratoconus (KCN).Methods:This retrospective case series comprised 161 eyes of 161 patients with KCN (104 men, 57 women; mean age, 22.35 ± 6.10 years). The participants were divided into four subgroups according to the Amsler-Krumeich classification. A Scheimpflug imaging system was used to measure the magnitude and axis orientation of ACA and PCA. The posterior-anterior corneal astigmatism ratio was also calculated. The results were compared among different subgroups.Results:The average amounts of anterior, posterior, and total corneal astigmatism were 4.08 ± 2.21 diopters (D), 0.86 ± 0.46 D, and 3.50 ± 1.94 D, respectively. With-the-rule, against-the-rule, and oblique astigmatisms of the posterior surface of the cornea were found in 61 eyes (37.9%), 67 eyes (41.6%), and 33 eyes (20.5%), respectively; corresponding figures in the anterior corneal surface were 55 eyes (32.4%), 56 eyes (34.8%), and 50 eyes (31.1%), respectively. A strong correlation (P ≤ 0.001, r = 0.839) was found between ACA and PCA in the different stages of KCN; the correlation was weaker in eyes with grade 3 (P ≤ 0.001, r = 0.711) and grade 4 (P ≤ 0.001, r = 0.717) KCN. The maximum posterior-anterior corneal astigmatism ratio (PCA/ACA, 0.246) was found in patients with stage 1 KCN.Conclusion:Corneal astigmatism in anterior surface was more affected than posterior surface by increasing in the KCN severity, although PCA was more affected than ACA in an early stage of KCN.

Highlights

  • Some researchers have reported that toric intraocular lens (IOL) implantation could be used to correct astigmatism in patients with KCN and cataract.[11,12]

  • posterior corneal astigmatism (PCA) has not been taken into consideration for toric IOL power calculation which is a possible reason for refractive error after surgery

  • The change in the posterior corneal surface plays a more subtle role than the anterior corneal surface in optical performance because of the smaller difference in refractive indices between the cornea and aqueous, and it has been thought that the magnitude of PCA in the normal population is clinically negligible

Read more

Summary

Introduction

Keratoconus (KCN) which is characterized by steepening. Biomicroscopic examination and Placido‐based corneal topography are usually used to detect KCN in daily practice. Characteristics of posterior corneal astigmatism in different stages of keratoconus.

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call