Abstract

In this paper we investigated the surface morphology and emission property of polymer velvet in a cathode test system powered by a ∼400 ns, ∼400 kV pulsed generator. After a series of pulse shots, the velvet surface exhibited an obvious decrease in the amount of emitters, namely, the smoothing of microprotrusions, indicating a lower field enhancement factor or a higher turn-on electric field than that for no shots. As the velvet cathode lifetime proceeded, the beam degradation was observed in terms of the voltage pulse length, maximum emission current, and rise time of diode current. Further, the average current density significantly decreased during a 100 pulse shot test, from 280 to 160 A/cm 2. The surface discharge caused many plasma spots on the velvet surface. The cathode plasma expands towards the anode, directly leading to the diode gap closure. The degradation in the velvet performance after high-current emission may be related to this behavior of cathode plasma. Finally, the electron emission mechanisms, how to affect the surface morphology of velvet, are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.