High-voltage vacuum insulator failure is generally due to surface flashover rather than insulator bulk breakdown. To study the characteristic of surface flashover channel, a diagnosis system to obtain the images of flashover channel is fabricated using a high speed frame camera, and results are presented by an investigation into the flashover of poly-methyl methacrylate insulator with gap spacing of 170 mm in vacuum under 180 ns quasi-square pulses. It is obtained that after formation of the flashover channel, the impedance of the flashover channel is inductive and the waveform of the measured voltage is determined by the inductance of the flashover channel directly.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.