Abstract
The main objective of this study was to investigate membrane fouling caused by natural organic matter (NOM). Flux measurement, fourier transform spectroscopy (FTIR), scanning electron microscopy (SEM) were employed to compare the surface morphology of fouled membrane and chemically cleaned membrane. Sodium hypochlorite (NaClO), sodium hydroxide (NaOH), hydrochloric acid (HCl) were used as chemical cleaning agents respectively. Flux analysis demonstrated that chemical cleaning have little effect on flux recovery. FTIR spectrometry revealed that polysaccharide and protein took the major responsibility for membrane fouling. SEM showed that foulants filled the pores and blocked the membrane surface which led to the flux decline.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.