Abstract

The high- T c superconducting (HTS) magnet is an important element for developing HTS power equipments such as the dc reactor of the inductive type superconducting fault current limiter (SFCL). In order to use the HTS magnet for the large-scale power system, its critical current needs to be high enough. Generally, the double pancake HTS magnet has the severe decrease in the critical current because of magnetic field perpendicular to the tape surface. To fabricate a high critical current magnet, we wound a solenoid with the stacked tape. In this paper, the characteristics of the critical current of the HTS solenoid wound with the stacked tape were investigated. The results of this research can be used as the background data for the design of the large-scale HTS magnet.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.