Abstract

High-risk medical devices often undergo modifications, which are approved by the US Food and Drug Administration (FDA) through various kinds of premarket approval (PMA) supplements. There have been multiple high-profile recalls of devices approved as PMA supplements. To characterize the quality of the clinical studies and data (strength of evidence) used to support FDA approval of panel-track supplements (a type of PMA supplement pathway that is used for significant changes in a device or indication for use and always requires clinical data). Descriptive study of clinical studies supporting panel-track supplements approved by the FDA between April 19, 2006, and October 9, 2015. Panel-track supplement approval. Methodological quality of studies including randomization, blinding, type of controls, clinical vs surrogate primary end points, use of post hoc analyses, and reporting of age and sex. Eighty-three clinical studies supported the approval of 78 panel-track supplements, with 71 panel-track supplements (91%) supported by a single study. Of the 83 studies, 37 (45%) were randomized clinical trials and 25 (30%) were blinded. The median number of patients per study was 185 (interquartile range, 75-305), and the median follow-up duration was 180 days (interquartile range, 84-270 days). There were a total of 150 primary end points (mean [SD], 1.8 [1.2] per study), and 57 primary end points (38%) were compared with controls. Of primary end points with controls, 6 (11%) were retrospective controls and 51 (89%) were active controls. One hundred twenty-one primary end points (81%) were surrogate end points. Thirty-three studies (40%) did not report age and 25 (30%) did not report sex for all enrolled patients. The FDA required postapproval studies for 29 of 78 (37%) panel-track supplements. Among clinical studies used to support FDA approval of high-risk medical device modifications, fewer than half were randomized, blinded, or controlled, and most primary outcomes were based on surrogate end points. These findings suggest that the quality of studies and data evaluated to support approval by the FDA of modifications of high-risk devices should be improved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.