Abstract

This paper examines the implications of pretreatment in the context of the likely behaviour of flocs in DAF units. Evidence indicates that the maximum floc size (dmax) of alumino-humic is scaled by the Kolmogorov length (eta) with dmax/eta approximately 1. A larger ratio exists when polymer is present. Data from the literature suggests that velocity gradient in the inlet chamber may exceed 1000 s-1, suggesting eta approximately 40 microns. This view of the response of floc to shear is supported by shear tests carried out on samples of floc withdrawn from flocculators at full scale water treatment works. Using an underwater CCTV camera, coupled with image analysis, it is shown that floc sizes in conventionally designed flocculators are much bigger than the sizes which are likely to exist in DAF units. Circumstantial evidence gained from water treatment works suggests that DAF units perform satisfactorily whatever the size of the incoming floc. From such evidence, the authors question the conventional design of the flocculators in association with DAF units.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.