Abstract

A wider operational bandwidth, a higher electromechanical coupling factor, and lower acoustic impedance are important requirements for ultrasound transducers for use across many applications. Conventional 2-2 piezoelectric composite transducers have been widely researched because of their wider bandwidth and higher sensitivity over their piezoelectric ceramic counterparts. In this paper, the fabrication of a novel 2-2 piezoelectric composite using magnetic force assembly is proposed to explore the potential of the transducer and to minimize mode coupling effect compared to 1–3 composites. To determine the desired transducer performance, such as the electromechanical coupling factor, the operational bandwidth, and the acoustic impedance, the design of a 2-2 composite should be considered using the mode-coupling theory and an effective medium model. The experimental results indicate that the electromechanical coupling factor and the −6 dB fractional bandwidth of the composite achieve values of 0.58 and 65.2%, respectively, which are comparable to those of traditional 1-3 piezoceramic/epoxy composites.