Abstract

The occurrence of volatile arsenic in natural gas, could lead to the poisoning of catalyst in processing equipment, and pose a serious threat to human health. In order to detect the total volatile arsenic in natural gas, this paper analyzed the characteristic and original mechanism of the volatile arsenic first, then a novel method was carried out by using silver nitrate solution, saturated potassium persulfate solution and concentrated nitric acid solution as sorption solution, followed by volatile arsenic determination with ICP-MS .The result showed that 2% silver nitrate solution had a good adsorption effect to volatile arsenic, and the recoveries of arsenic ranged from 87%~103%, which basically met the demand for the rapid detection of volatile arsenic in natural gas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.