Abstract

A number of beam position monitors are being installed at the Front End Test Stand H⁻ ion source at the Rutherford Appleton Laboratory, UK, as part of the 3 MeV medium energy beam transport. The FETS ion source delivers pulses up to 2 ms long at a rate up to 50 Hz and a maximum current of 60 mA, with a 324 MHz micro-bunch structure imposed by the frequency of the FETS RF acceleration cavity. The response of an in-house designed button BPM has been simulated and then characterised on a wire-based test-rig and the results are presented. The output from a custom algorithm running on a commercial PXI-based FPGA signal processing system is evaluated using test signals from both a function generator and the BPM in the test-rig, to verify the speed and precision of the processing algorithm. The processing system can determine the beam position in eight BPMs, with a precision of better than 20 microns, within one microsecond of the signal sampling being completed. Work is ongoing to reduce the processing time to below 300 ns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.