Abstract
This paper presents a technique for configuring wastewater process simulations so that the hydraulic characteristics are similar to the real plant. Residence time distribution (RTD) tests are performed on two biological nutrient removal pilot plants. The RTD tests proved valuable for evaluating mixing effectiveness, volume utilisation and for determining an appropriate hydraulic topology for the dynamic models of the pilot plants. As a result of this work, simulation execution times became much faster due to a significant reduction in the number of effective stirred tanks required in the model. The work also identified short circuiting and dead zones in the pilot plants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.