Abstract

A stormwater facility consisting of a hydrodynamic separator as an overflow device, an open concrete storage tank and two subsequent open earth retention basins was investigated. The results are used to characterise the qualitative performance of the storage tank. By evaluating the cumulative runoff volume and settleable solids load it is shown that the qualitative performance can be characterised by two effects: pollutants are retained because runoff is stored until the tank starts to overflow; pollutants are retained because the tank operates as a clarifier during the overflow period. The influencing factors on these two processes are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.