Cerebral ischemia during carotid endarterectomy occurs via several mechanisms: inadequate collateral blood flow during carotid cross-clamping, thromboembolism due to carotid manipulation, and/or rethrombosis at the surgical site. Perioperative strokes increase not only the morbidity of endarterectomy but also its short- and long-term mortality. However, while several predictors of cerebral ischemia have been identified, precise individual risk is hard to assess. Since nonselective shunting during carotid cross-clamping is neither risk-free nor eliminates perioperative stroke, it is advisable to apply intraoperative monitoring techniques for detection and reversal of cerebral ischemia, which may occur at various stages of the procedure. This chapter addresses the methods available for monitoring, with an emphasis on neurophysiologic techniques, which are preferable given their direct assessment of how a decrease in cerebral blood flow impacts brain function. These include electroencephalography, somatosensory evoked potentials, and transcranial motor evoked potentials. Details regarding the methodology, advantages, disadvantages, and interpretation of these tests will be discussed within the anatomic, physiologic, surgical, and anesthetic contexts.