Abstract
Self-heating in AlGaN/GaN HFETs was investigated using electrical analysis and micro-Raman thermography. Two typically employed electrical methods were assessed to provide a simple means of extracting average channel temperatures in devices. To quantify the accuracy of these electrical temperature measurements, micro-Raman thermography was used to provide submicron resolution temperature information in the source-drain opening of the devices. We find that electrical methods significantly underestimate peak channel temperatures, due to the fact that electrical techniques measure an average temperature over the entire active device area. These results show that, although electrical techniques can be used to provide qualitative comparisons between different devices, they have challenges for the accurate estimation of peak channel temperatures. This needs to be taken into account for lifetime testing and reliability studies based on electrical temperature measurements.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.