Abstract

Experimental data on changes taking place in the properties of ion exchangers after prolonged use in the purification of low-activity waste water in an experimental industrial plant designed for the purification of laboratory waste are presented. Under those conditions the ion exchangers become darkened and break up. The dynamic exchange capacity falls by 30 to 45%. The coefficients representing the purification of the solutions from Cs137, Sr90 and S 35 are nevertheless no lower than those achieved with new ion exchangers. The capacity of anion exchanger AN-2F may be increased by 20% after treating with a 0.5 N solution of nitric acid. After three years operation, the ion exchangers are still suitable for further use in the purification plant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.