Abstract

Introduction. The intensive development of radio and electrical communications, as well as various electronic devices, leads to the electromagnetic pollution of the environment.Aim. In this work, the authors set out to study the serum iron parameters of rats exposed to chronic electromagnetic radiation (EMR) of the decimeter range.Materials and methods. The research was carried out on rats that were divided into experimental and control groups. The experimental group was further divided into 4 subgroups of 10 animals each, which were subsequently exposed to electromagnetic radiation at a frequency of 460 MHz (Volna-2 apparatus) for 1, 2, 3 and 4 weeks. The control group (10 rats) was exposed to pretend irradiation, with the device being turned off. The following parameters were estimated: serum iron (SI), total iron-binding capacity (TIBC) and unsaturated iron-binding capacity (UIBC) of serum, transferrin saturation (TS), as well as serum concentrations of transferrin, haptoglobin, malondialdehyde and lipid hydroperoxides.Results. Differences in the SI concentration were found in the subgroups of animals exposed to radiation for 3 and 4 weeks (44.1 ± 3.1 μmol/l and 56.8 ± 4.4 μmol/l, respectively), as compared to the control group (30.5 ± 3.3 μmol/l). In experimental animals, TIBC increased by 41 % (p <0.05) — relative to the control group (110.8 ± 10.1 μmol/l) — only following 3 weeks of irradiation (156.2 ± 18.2 μmol/l), with a decrease in TIBC to 123.6 ± 16.4 μmol/l being noted during the 4th week. The concentration of transferrin increased from 45.6 ± 8.0 μmol/l (control) to 81.0 ± 11.5 μmol/l during the 3rd week of radiation exposure, with a decrease to 55.9 ± 6.7 μmol/l being observed during the 4th week. TS increased from 27.5 % (control) to 45.9 % only following 4 weeks of irradiation. The content of lipid hydroperoxides and malondialdehyde in the blood of irradiated rats was higher, as compared to the control animals. The serum concentration of haptoglobin amounted to 26.7 % in the control group, reaching 53.8 mg % and 47.8 mg % following 3 and 4 weeks of exposure, respectively.Conclusion. The total chronic exposure to decimetric EMR produces an oxidising effect on organisms.

Highlights

  • The intensive development of radio and electrical communications, as well as various electronic devices, leads to the electromagnetic pollution of the environment

  • study the serum iron parameters of rats exposed to chronic electromagnetic radiation

  • The experimental group was further divided into 4 subgroups of 10 animals each

Read more

Summary

Материалы и методы

Исследование проведено на белых крысах линии Вистар массой 250–300 г, содержавшихся в обычных условиях вивария. Экспериментальная группа подразделялась на четыре подгруппы по 10 животных в каждой, которые подвергались тотальному облучению ЭМИ в течение 1, 2, 3 и 4 недель. Для облучения использовалось дециметровое излучение (частота 460 МГц), генерируемое физиотерапевтическим аппаратом «Волна-2» (Россия). Ежедневное облучение осуществлялось в течение 20 минут при плотности потока мощности 30 мкВт/см. Контрольная группа животных (10 крыс) подвергали «ложному» облучению в тех же условиях, что и экспериментальные, только при выключенном аппарате. Сывороточное железо (СЖ) и ОЖСС определяли с помощью набора реагентов IRON Liquicolor фирмы “Human” (Германия). В соответствии с инструкцией к набору, концентрация железа при определении СЖ измерялась непосредственно в сыворотке, а при определении ОЖСС — в супернатанте после осаждения избытка трехвалентного железа, добавленного в сыворотку для насыщения транферрина железом. Показатели обмена железа и продуктов перекисного окисления липидов после облучения дециметровым электромагнитным излучением (M±m) Table 1. Parameters of iron metabolism and lipid peroxidation products following decimetric electromagnetic irradiation (M ± m)

Показатели Parameters
Findings
Экспериментальная группа Experimental group
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call