Abstract

Sleep nasendoscopy can be used to identify the site of snoring but questions remain about how well a short assessment during drug-induced sleep reflects the natural condition. To investigate the uniformity of snoring during natural sleep we studied five patients (three men, two women) referred by their GPs for treatment of their snoring. A digital audio tape recorder captured the free-field snore sound at different times of night in hospital. Acoustic Crest Factor values were calculated on the 15 recordings made, having previously demonstrated that high crest factor values distinguish palatal from non-palatal snoring at sleep nasendoscopy. Some recordings showed reproducibility, but others showed substantial changes between recordings an hour apart. We infer that the snoring mechanism may change in some individuals during the night, with or without a change of snore site. We conclude a single recording, as in sleep nasendoscopy, may not be representative.