Abstract
The aims of this investigation were to histologically evaluate in monkeys the effect of a repetitive mechanical trauma alone on the peri-implant tissues, and the effect of a repetitive mechanical trauma in combination with ligature-induced peri-implantitis on the peri-implant tissues. The study used 5 male cynomolgus monkeys. Prior to the start of the study, all premolars and the first and second molars in the mandible were extracted. After a healing period of 12 weeks, following tooth extraction, split/full thickness flaps were elevated on both sides of the mandible in order to expose the bony ridge. Four implants, of 3.75 mm in diameter and 7 mm in length, were then inserted on each side and the flaps were readapted and sutured in place. Following a healing period of 16 weeks, the second stage procedure was performed, impressions were taken, and custom-made crowns using a non-precious metal alloy were fabricated and inserted on all implants 4 weeks after abutment connection. At the same time peri-implantitis was induced on one side of the mandible by placing plaque-retentive ligatures around the implants. On the other side, an oral hygiene program consisting of thrice weekly brushing with a toothbrush and flour of pumice mixed with 2% chlorhexidine was initiated. Four months later, a repetitive mechanical trauma was initiated on implants 1 and 2 on both sides in the mandible. Consequently, a split mouth design was obtained: 1) test 1=ligature-induced peri-implantitis alone (LPNO); 2) test 2=ligature-induced peri-implantitits with a repetitive mechanical trauma (LPMT); 3) test 3=healthy peri-implant tissues with a repetitive mechanical trauma (MT); and 4) control (NO)=healthy peri-implant tissues with no repetitive mechanical trauma. Following 16 weeks of repetitive mechanical trauma the animals were sacrificed. Histologic observations and computed-assisted histometric and histomorphometric analyses were performed to determine the amount of peri-implant bone loss and the percentage of direct mineralized bone-to-implant contact around each endosseous oral implant. Histologically, all implants yielded osseointegration at the light microscopic level. There was a significant difference regarding the mean direct mineralized bone-to-implant contact length as a fraction of the total implant length between the healthy (i.e., MT and NO) and diseased sites (i.e., LPNO and LPMT) (P < 0.05). When comparing the percent of direct mineralized bone-to-implant contact for the 2 best threads of each implant and group, no significant difference (P=0.675) could be detected. Under the conditions of this study, the repetitive mechanical trauma showed no histologic effect on the peri-implant bone loss neither in healthy nor in diseased implant sites. The effects of excessive loading on osseointegration are presently not clearly understood. The key problem seems to be the determination when loading on implants exceeds the physiological range of bone adaptation which may then cause implant failure. Further research to elucidate this problem is essential.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.