Abstract

Non-invasive Doppler-shift ultrasound, together with spectral analysis, have been used to study the changes in internal carotid artery flow velocity patterns that occur with cerebral vasoconstriction and vasodilation provoked by over-breathing and breath-holding. Significantly different waveform shapes, characteristic for each vessel, were demonstrated from the internal and external carotid arteries, making identification of the internal carotid certain. In 5 healthy subjects over-breathing for 3 minutes significantly lowered the mean height of the internal carotid waveform by an average of 32% (p less than 0.001). Breath-holding for 40-60 seconds raised the mean height by an average of 31% (p less than 0.001). The pulsatility index of the waveforms varied inversely to mean height. These results show that the effects of cerebral dilation or constriction are easily detected by flow-velocity changes in the internal carotid artery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.