Abstract

BackgroundThe purpose of this study was to determine the effect of stress on left-to-right shunting in patients with atrial septal defect (ASD) and to investigate if the degree of shunting, cardiac output (CO), and right ventricular (RV) volumes are related to exercise capacity.MethodsTwenty-six patients with a secundum ASD and 16 healthy volunteers were studied with rest/stress cardiac magnetic resonance using 20 µg/kg/min dobutamine and 0.25–0.75 mg atropine to quantify CO, pulmonary to systemic flow ratio (QP/QS), and left ventricular (LV) and RV volumes. Peak oxygen uptake (VO2peak) was determined on ergospirometry.ResultsIn patients with ASD the QP/QS decreased from 2.0 ± 0.2 at rest to 1.5 ± 0.1 (P < 0.001) during dobutamine stress (n = 20) and shunt volume per heartbeat decreased from 70 ± 9 to 38 ± 9 mL (P < 0.001). However, absolute shunt volume per minute was unchanged (5.1 ± 0.8 vs. 4.5 ± 1.0 L/min, P = 0.32) explained by a higher increase in systemic CO during stress (90 ± 11%) compared with pulmonary CO (43 ± 7%, P < 0.001). In ASD patients, VO2peak correlated with aortic CO during stress (r = 0.77) and QP/QS at rest (r = −0.48) but not during stress (P = 0.09). VO2peak did not correlate with RV volumes in patients.ConclusionPulmonary to systemic flow ratio and shunt volume per heartbeat decrease during stress in ASD patients. This may be explained by an enhanced LV diastolic function during stress and may have implications to detect disturbances in LV compliance in ASD patients. A high systemic CO during stress is a strong predictor of exercise capacity.