Abstract

Microbial surveillance of environmental bacteria was performed in order to study the microbial changes in a newly established hospital building. Airborne bacteria and surface-associated bacteria on floors and sinks were systematically collected between 2002 and 2005. The number of isolates obtained from frequently used floors was significantly higher than that obtained from those floors used less often. A significant increase in Staphylococcus aureus, the appearance of Pseudomonas aeruginosa, and changes among species of Gram-negative bacilli were observed 8-11 months after the new building had been opened. Furthermore, pulsed-field gel electrophoresis (PFGE) typing of meticillin-resistant S. aureus (MRSA) and P. aeruginosa showed that strains of the same PFGE groups were isolated from different sinks, floors and the adjoining old buildings. The number of MRSA isolates obtained from the new building increased as time passed. The sinks from which P. aeruginosa strains of the same PFGE type were isolated are connected by the same drainage pipe. Human movement has considerable effects on bacterial flora and their subsequent spread.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.