Abstract

Purpose: To compare the change in continuous curvilinear capsulorhexis (CCC) size after implantation of four types of three-piece foldable intraocular lenses (IOLs) and determine whether initial CCC size and IOL characteristics play a role in the change.Methods: This study comprised 133 eyes that had phacoemulsification and in-thebag implantation of one of four types of foldable IOLs: Alcon AcrySof™ MA30BA (n = 36); lovision™ 127 (n = 29); Mentor ORC MemoryLens™ (n = 39); Allergan PhacoFlex II™ (n = 29). Photographs of the CCCs were taken with a digital retinograph 1 day and 6 months after surgery. Using image-analysis software, the CCC surface was measured and changes between 1 week and 6 months were evaluated. Characteristics of the IOLs including overall diameter, optic thickness, and haptic centrifugal force were measured with micrometric tools.Results: The median change in CCC surface size at 6 months was +5.5% in the lovision group, indicating a slight enlargement. This finding was significantly different from that in the other three IOL groups (P < .0001), which had a tendency toward CCC contraction. Median change in CCC size was −2.3% in the MemoryLens group, −2.8% in the AcrySof group, and −6% in the PhacoFlex group. The MemoryLens was the most predictive IOL, with the smallest standard deviation; it was the only group in which no patient developed CCC contraction of more than 10%. Although the lovision and PhacoFex IOLs have common physical characteristics except for optic thickness (lovision 30% thicker), the CCCs in the lovision group were significantly more stable (P < .0001). Results indicate that the high centrifugal haptic force associated with acrylate/methacrylate polymer optics of the AcrySof and MemoryLens IOLs may prevent CCC contraction of greater than 10% in 97.4% of cases.Conclusion: Although there were statistically significant differences, patients in all four three-piece foldable IOL groups had good CCC stability. However, the more stable and predictable CCCs were in the IOL groups that had the strongest centrifugal haptic force and an acrylate/methacrylate polymer optic (AcrySof and MemoryLens).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.