Abstract

BackgroundAbnormalities in acetabular orientation can promote the development of hip osteoarthritis, femoro-acetabular impingement, or even acetabular cup malposition. The objective of the present study was to determine whether pedicle substraction osteotomy (PSO) to correct sagittal spinal imbalance affected acetabular orientation. HypothesisPSO performed to correct sagittal spinal imbalance affects acetabular orientation by changing the pelvic parameters. Materials and methodsThis was a descriptive study in which two observers measured the acetabular parameters on both sides in 19 patients (38 acetabula) before and after PSO for post-operative flat-back syndrome. Mean time from PSO to post-operative measurements was 19months. Measurements were taken twice at a 2-week interval, on standing images obtained using the EOS® imaging system and sterEOS® software to obtain 3D reconstructions of synchronised 2D images. Acetabular anteversion and inclination were measured relative to the vertical plane. Mean pre-PSO and post-PSO values were compared using the paired t-test, and P values lower than 0.05 were considered significant. To assess inter-observer and intra-observer reproducibility, we computed the intra-class correlation coefficients (ICCs). ResultsThe measurements showed significant acetabular retroversion after PSO, of 7.6° on the right and 6.5° on the left (P<0.001). Acetabular inclination diminished significantly, by 4.5° on the right and 2.5° on the left (P<0.01). Inclination of the anterior pelvic plane decreased by 8.4° (P<0.01). Pelvic incidence was unchanged, whereas sacral slope increased by 10.5° (P<0.001) and pelvic tilt decreased by 10.9° (P<0.001). The ICC was 0.98 for both inter-observer and intra-observer reproducibility. ConclusionChanging the sagittal spinal alignment modifies both the pelvic and the acetabular parameters. PSO significantly increases sacral slope, thus inducing anterior pelvic tilt with significant acetabular retroversion. The measurements obtained using sterEOS® showed good inter-observer and intra-observer reproducibility. To our knowledge, this is the first study of changes in acetabular version after PSO.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.