Phthalates (PAEs) are pervasive in indoor environments. In this study, two migration pathways of di-n-octyl phthalate (DNOP) from a source to dust were investigated using microchambers in a thermostatic incubator: (1) mass transfer through direct contact with source surfaces; (2) mass transfer through air. A 20-day emission experiment with settled dust was performed at 30 °C. Significantly higher concentrations were observed in dust that was in direct contact than in dust that was not, which indicated that direct contact enhanced the sorption of the dust on DNOP. The difference between source and non-source surface was low of the migration of the DNOP in the dust. In addition, the temperature and dust loading and diffusion distance were considered. The results suggested that the temperature did not considerably influence the difference between source and non-source surface; however, the difference increased with an increase in dust loading. These results can help understand the mass transfer mechanism of PAEs to implement effective control measures and reduce the human exposure to PAEs in indoor environments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.