Abstract

Mini-tablets (MTs) with losartan potassium were developed to treat the rare disease Epidermolysis Bullosa. The focus was placed on transfer and scale-up of a direct compressible formulation from the compaction simulator STYL’One Evo (CS) to the rotary tablet press Korsch XM 12 (RP). Transfer of tabletability and compactibility profiles from CS to RP did not show good agreement, e.g. at a tableting pressure of 125 MPa mean tensile strengths (TS) of 4 MPa on CS and 1–1.5 MPa on RP were reached. These results highlight the impact of the feed frame on final product qualities depending on process and material factors. In the scale-up studies the critical quality attributes (CQAs) mass variation, content uniformity, TS and disintegration time were investigated. After an appropriate run-up time, most CQAs reached a plateau, after reaching a balance between influx, efflux and distribution of lubricant in the feed frame. TS values of 1–2 MPa, disintegration times of max. 50 s, mass variation of 0.9–2.2 % (CV) and acceptance values below 15.0 were reached depending on chosen process parameters.