Abstract

Comparison of the accuracy of intraocular lens (IOL) power calculation formulas (SRK II, SRK/T, Holladay 1, Hoffer Q and Barrett II Universal, Haigis) in pediatric cataract surgery using optical biometry. This prospective study included seventy eyes of 70 patients between ages of 3-15 who had undergone cataract surgery with IOL implantation. Anterior segment parameters and axial length (AL) were measured with an optical biometer. Barrett II Universal formula results were used to determine the diopter of implanted IOL. Postoperative refraction was taken at first month, and differences from the estimated refractive value [mean absolute predictive error (APE)] were compared between formulas. Formulas were also compared according to AL. The lowest APE was achieved with Barrett II formula (0.64 ± 0.73D) and the highest with Haigis formula (1.06 ± 0.84D) in the whole study population (p < 0.01). APE values were lowest with Holladay 1 (0.79 ± 0.71D) and highest with Haigis (1.44 ± 0.92D) in patients with an AL ≤ 22mm; lowest APE was achieved with Barrett II (0.47 ± 0.54D) and highest with Haigis (0.84 ± 0.72D) in patients with an AL > 22mm. Barrett II formula had the best results in eyes with average AL, and SRK/T and Holladay 1 formulas were better in eyes with shorter AL. Haigis formula statistically had the highest predictive error in all formulas.