Abstract
After observations of cloudiness in the perfusion circuit at open intracardiac operations, laboratory experiments showed a precipitate in a Hartmann's solution (compound sodium lactate solution, Ringer-lactate) and sodium bicarbonate based priming fluid used for cardiopulmonary bypass. The precipitate was found to consist of calcium carbonate crystals. The crystals were not dissolved by adding plasma proteins, nor were they sufficiently cleared from the extracorporeal circuit by a 40 microns filter in the arterial line. The crystals may embolise in microvascular beds and thus be a cause of postoperative morbidity. The practice of adding sodium bicarbonate to the pump prime may be unnecessary.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.