Abstract

A building that is composed of coupled shear walls with dampers, CFT columns, and flat plate slabs is one of the types of buildings that can be reused, with low repair cost, after an earthquake. To evaluate the lateral load-deflection relation of the newly designed CFT column/flat plate connection, two series of experimental studies were carried out: lateral loading tests for interior column/slab connections, and element tests for torsional stiffness and strength. Lateral load-deflection behavior of the CFT column/flat plate connection were examined using macro models proposed in this study, and good agreements are obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.