Abstract

This paper reports the testing of five reinforced concrete continuous beams strengthened in flexure with externally bonded carbon-fibre-reinforced polymer (CFRP) laminates. All beams had the same geometrical dimensions and internal steel reinforcement. The main parameters studied were the position and form of the CFRP laminates. Three of the beams were strengthened using different arrangements of CFRP plate reinforcement, and one was strengthened using CFRP sheets. The performance of the CFRP-strengthened beams was compared with that of an unstrengthened control beam. Peeling failure was the dominant mode of failure for all the strengthened beams tested. The beam strengthened with both top and bottom CFRP plates produced the highest load capacity. It was found that the longitudinal elastic shear stresses at the adhesive/concrete interface calculated at beam failure were close to the limiting value recommended in Concrete Society Technical Report 55.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.