Abstract
Grid independence verification was implemented to improve the reliability of CFD numerical simulation in pigsty. The effects of four different grid numbers on airflow and temperature simulation of 0.4m, 1.0m and 1.6m heights were compared. The results showed that the third method of mesh generation and the grid numbers about 2.09 million were more suitable for this pigsty model. The average relative error of airflow velocity and temperature between the simulated and the measured alues were 7.1% and 3.8% respectively, the average NMSE were 0.0012 and 0.0066 respectively. Therefore, grid independence verification is of great significance for CFD numerical simulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.