Abstract

The influences of the conventional header configuration used in industry at present on the fluid flow distribution in plate-fin heat exchanger were numerically investigated. The numerical results showed that the fluid flow maldistribution is very serious in the heat exchanger. The header configuration with perforated plate was brought forward for the first time. The computational results indicated that the improved header configuration can effectively improve the performance of fluid flow distribution in the heat exchanger. The fluid flow distribution for the header configuration with curving perforated plate is more uniform than for the header configuration with plane perforated plate. The absolute degree of fluid flow nonuniformity in plate-fin heat exchanger has reduced from 3.47 to 0.32 by changing the header configuration. The numerical results are compared with the experimental results. They are basically consistent which indicates that the mathematical model and the calculating method are reliable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.