Abstract

The VM refrigerator with power being supplied by liquid nitrogen shows great potential for application below 10K. The 2D axisymmetric model refers to actual geometry under oscillating flow conditions is carried out using FLUENT software. The lowest temperature, the pressure in three cavities, the temperature profile along the regenerator is presented. The simulation results show good agreement with available data. Then the regenerator between cold and middle cavity is optimized to obtain the lowest temperature, it is filled with stainless steel screens and lead shot. It is found that there exists an optimal ratio of stainless steel screens and lead in the same length regenerator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.