Abstract

In this work, we present the validation of a numerical model of a greenhouse thermally in-sulated on three sides with a tomato crop. A CFD software (Ansys-Fluent) was used to solve the numerical model. The discrete ordinate model was included to solve the radiative trans-fer equation. The results of the numerical model were compared with the values of air tem-perature observations at different points in the greenhouse. Good agreement was obtained between the simulated and measured values, with coefficients of determination R2 = 0.77, R2 = 0.84, R2 = 0.99, and R2 = 0.89 for the temperatures of the points 10 cm, 80 cm, and 210 cm above the ground and the average temperature in the greenhouse, respectively. A third-order polynomial curve was drawn between the simulated and measured values of relative humidity in the greenhouse. These R2 values are 0.9786 and 0.7165, the simulated and measured relative humidity, respectively. The simulation results showed low velocity values with an average of 0.525 m/s located between 1.5 m and 2 m from the ground.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.