Abstract

The U. S. Department of Energy (DOE) is currently supporting the development of a next generation nuclear plant (NGNP). The NGNP is based on the very high temperature reactor (VHTR), which is a Generation IV gas-cooled reactor concept that will use helium as the coolant. Computational fluid dynamics (CFD) calculations are to be employed to estimate the details of the flow and heat transfer in the lower plenum where the heated coolant empties before exiting the reactor vessel. While it is expected that CFD will be able to provide detailed information about the flow, it must be validated using experimental data. Detailed experimental data have been taken in the INL’s matched index of refraction (MIR) facility of a scaled model of a section of the prismatic VHTR lower plenum. The present article examines the data that were taken to investigate the suitability of such data to be a validation data set for CFD calculations. CFD calculations were made to compare with the MIR data to explore potential issues and make recommendations regarding the experiment.