Abstract

This study presents a detailed methodology for non-intrusive measurement of cooling air mass flow rate that enables an overall machine evaluation. This approach enables the simultaneous measurement of air mass flow with shaft torque at differing operating points while minimising the change in air flow introduced by the measurement system. The impact of geometric parameters in the designed system is investigated using a detailed 180° computational fluid dynamics (CFD) model. Special attention was paid to minimising their influence on pressure drop, the mass flow rate through the machine, and measurement uncertainty. Based on the results of this investigation, the system was designed and manufactured, and the experimentally measured data was used to validate the CFD predictions. For the as optimal identified configuration, the flow rate is predicted to decrease by 2.2% relative to unrestricted operation. The achieved measurement uncertainty is ± 2.6% at synchronous speed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.