Abstract

ABSTRACTThe flow and heat transfer mechanisms of mist/air film cooling are studied in this paper with three hole types under three blowing ratios. The velocity vectors and three-dimensional contours of the vortices are shown in this paper in order to investigate the mist/air cooling characters with different hole types. Both the span averaged and centerline film cooling effectiveness are studied in this paper to compare the cooling performance of three cooling hole types.Mist/air cooling performances of cylindrical hole, fan-shaped hole, and console hole are studied numerically. Flow structures of mist/air jets are studied. Both centerline and span averaged film cooling effectiveness are studied. Results show that the kidney vortex uplifts the mists further away from the flat plate and the antikidney vortex uplifts the mists near the lateral edge of the hole gradually. Mists enhancement on cooling effectiveness is significantly impaired at a higher blowing ratio in cylindrical hole and fan-shaped hole cases. The cooling effectiveness can maintain a relatively high value at each blowing ratio in console hole cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.