Abstract

Ultrasound (US) is often the first-line imaging modality in the evaluation of the renal masses. If the findings of a renal mass do not meet all of US criteria of a simple cyst, it should be characterized further. Usually characterization of indeterminate renal masses is well done with CT or MRI, but sometimes it is inconclusive on these imaging techniques. In thoses cases and in patients to whom radiation exposure or use of iodine or gadolinium contrast agents is undesirable, contrast-enhanced US (CEUS) may be a valuable alternative to evaluate those problematic renal masses. CEUS may replace CECT or CEMRI if the patient has marginal or poor renal function, hypersensitivity to iodine contrast agent, or fear of radiation exposure. CEUS has long history in medical US but drew attention only recently. With the first generation microbubble agents several studies showed added value of CEUS as compared to the conventional Doppler US. We reported that CEUS provided better visualization of tumor vascularity in indeterminate cystic renal lesions than other imaging modalities using a first-generation agtent. The most important limitation of the first generation agent was that it could not provide an enough duration of contrast enhancing effect. With introduction of the second generation microbubble agents with better stability and duration of contrast effect, CEUS examination became a practical alternative of CECT or CEMRI in evaluation of problematic renal masses. We do not think that CEUS will be used routinely in US examination of renal masses like contrast enhancement is routine in CT for renal masses. However, we are sure that CEUS will be a valuable imaging technique if it is used in well selected cases of problematic renal masses. In evaluating problematic renal masses, CEUS may reveal findings that were not seen or confirm findings equivocal at other imaging studies. Results of CEUS can be analyzed qualitatively as to the presence or absence of enhancement, vascular pattern and heterogeneity etc. Quantitative analysis can be done on peak intensity, time to peak, and rate of wash-in and wash-out, etc.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.