Abstract

OBJECT This study compared the safety and efficacy of treatment with the PRESTIGE LP cervical disc versus a historical control anterior cervical discectomy and fusion (ACDF). METHODS Prospectively collected PRESTIGE LP data from 20 investigational sites were compared with data from 265 historical control ACDF patients in the initial PRESTIGE Cervical Disc IDE study. The 280 investigational patients with single-level cervical disc disease with radiculopathy and/or myelopathy underwent arthroplasty with a low-profile artificial disc. Key safety/efficacy outcomes included Neck Disability Index (NDI), Neck and Arm Pain Numerical Rating Scale scores, 36-Item Short Form Health Survey (SF-36) score, work status, disc height, range of motion, adverse events (AEs), additional surgeries, and neurological status. Clinical and radiographic evaluations were completed preoperatively, intraoperatively, and at 1.5, 3, 6, 12, and 24 months postoperatively. Predefined Bayesian statistical methods with noninformative priors were used, along with the propensity score technique for controlling confounding factors. Analysis by independent statisticians confirmed initial statistical findings. RESULTS The investigational and control groups were mostly similar demographically. There was no significant difference in blood loss (51.0 ml [investigational] vs 57.1 ml [control]) or hospital stay (0.98 days [investigational] vs 0.95 days [control]). The investigational group had a significantly longer operative time (1.49 hours vs 1.38 hours); 95% Bayesian credible interval of the difference was 0.01-0.21 hours. Significant improvements versus preoperative in NDI, neck/arm pain, SF-36, and neurological status were achieved by 1.5 months in both groups and were sustained at 24 months. Patient follow-up at 24 months was 97.1% for the investigational group and 84.0% for the control group. The mean NDI score improvements versus preoperative exceeded 30 points in both groups at 12 and 24 months. SF-36 Mental Component Summary superiority was established (Bayesian probability 0.993). The mean SF-36 PCS scores improved by 14.3 points in the investigational group and by 11.9 points in the control group from baseline to 24 months postoperatively. Neurological success at 24 months was 93.5% in the investigational group and 83.5% in the control group (probability of superiority ~ 1.00). At 24 months, 12.1% of investigational and 15.5% of control patients had an AE classified as device or device/surgical procedure related; 14 (5.0%) investigational and 21 (7.9%) control patients had a second surgery at the index level. The median return-to-work time for the investigational group was 40 days compared with 60 days for the control group (p = 0.020 after adjusting for preoperative work status and propensity score). Following implantation of the PRESTIGE LP device, the mean angular motion was maintained at 12 months (7.9°) and 24 months (7.5°). At 24 months, 90.0% of investigational and 87.7% of control patients were satisfied with the results of surgery. PRESTIGE LP superiority on overall success (without disc height success), a composite safety/efficacy end point, was strongly supported with 0.994 Bayesian probability. CONCLUSIONS This device maintains mean postoperative segmental motion while providing the potential for biomechanical stability. Investigational patients reported significantly improved clinical outcomes compared with baseline, at least noninferior to ACDF, up to 24 months after surgery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call