Abstract

A philosophy for the improvement of the extraction of controlled dc power from a polyphase ac supply line is presented. Extension of this philosophy for the interface of synchronous polyphase networks is briefly indicated. The needed kilovolt-ampere capacity of the supply line is reduced to nearly two thirds of the capacity needed for conventional controlled ac/dc converter systems. The new system requires only a small fraction of the physical weight of conventional converters. The improvements are derived from the interposition of a modulated high-power frequency carrier between the linked systems for the purpose of reconciliation of their conflicting characteristics. The harmonic content of the ac-phase currents is greatly reduced. The system operates with internal frequencies near 10 kHz; efficiencies in the upper nineties have been attained with this type of converter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.